To measure a defined section in Shotcut, move to its start, click Reset in the Audio Loudness scope, play continuously to the chosen end, and pause there. Read Integrated loudness and Loudness range after playback; don’t treat readings gathered after timeline jumps as statistics for that section. The scope measures the preview player, and Shotcut’s documentation warns that seeking can make readings inaccurate.
Set and measure the interval
- Decide the exact start and end of the section you want to assess. Use timeline timecode or another repeatable project reference to record both points; these are your measurement boundaries, not a claim about how the scope defines a segment.
- Seek to the start. Once the playhead is at the intended position, click Reset in the Audio Loudness scope. Reset after positioning, not before a later seek.
- Click Play and let playback proceed continuously. Avoid seeking, restarting, or jumping elsewhere before the end. If playback is interrupted or you seek, do not record the accumulated result as a clean measurement of the planned interval; position at the start, reset, and repeat the pass.
- When playback reaches the chosen end, click Pause. Record Integrated loudness and Loudness range for the played duration. Also record the changing Momentary, Short term, Peak, and True peak observations if they matter to your review.
Shotcut documents Momentary, Short term, Peak, and True peak as changing during playback, while Integrated loudness and Loudness range apply to the duration played. See the Audio Loudness scope guide for the scope’s metrics and segment-measurement procedure. The guide also notes that its display can be customized, so confirm the labels shown in your scope before recording values.
Use a measurement worksheet
This hypothetical example shows how to make the result auditable; the numbers and observations are illustrative, not Shotcut readings or a delivery recommendation. Say a creator wants to review a 20-second dialogue-and-music section from 00:01:10 to 00:01:30.
| Record | Hypothetical observation | Decision |
|---|---|---|
| Target interval | 00:01:10–00:01:30 | Use these same boundaries if repeating the review. |
| Reset and start | Reset at 00:01:10, then Play | Pass is valid only if playback proceeds from this start without a seek. |
| Continuity and end | No interruption noted; paused at 00:01:30 | If a jump occurred or the endpoint was missed, repeat from the start. |
| Dynamic observations | Momentary and Peak changed during playback; note any relevant observed values and when they occurred | Use these as time-varying observations, not as the interval’s final Integrated loudness or Loudness range. |
| End-of-pass statistics | Record the displayed Integrated loudness and Loudness range after pausing | Label them with the interval and pass; do not invent missing values. |
For a useful comparison, the author’s recommended method is to repeat the same boundaries and reset-and-play procedure, then note whether the relevant observations differ. This is a record-keeping suggestion, not a documented feature that compares passes automatically.
Limits and what to do next
A reset does not make a discontinuous pass representative of the intended section. A reading after a jump may include playback from outside the planned boundaries or otherwise be inaccurate; the documentation does not specify how such contamination is calculated. Treat an interrupted pass as inconclusive and measure again from the recorded start.
The scope reports loudness metrics for the preview player. Its readings alone do not determine whether a mix meets a delivery specification, which adjustment to make, or what an exported file will measure. If the recorded result is outside a delivery limit, first confirm the required target and the interval you measured. Decide separately whether to adjust the mix; then measure the intended interval again after the change. A timeline measurement is not a substitute for checking the final exported file when delivery compliance matters.
The Shotcut scope documentation describes the displayed metrics and warns about seeking, but does not define a tolerance for interrupted playback or promise a particular result for any interval.
Common questions
Can I seek within the section and keep measuring?
Not for a clean interval reading. The guide warns that seeking may make readings inaccurate. Restart the measurement from the intended start after a seek.
Should I read Integrated loudness while playback is moving?
For a defined segment, follow the documented sequence: pause at its end, then observe Integrated loudness and Loudness range. Momentary, Short term, Peak, and True peak change during playback.
Does a valid reading mean the mix is approved?
No. It is a measurement record for the played interval, not a mixing decision or proof of delivery compliance. Compare it with the applicable delivery requirement and assess any needed adjustment separately.
Sources and next step
This guide interprets public documentation and uses explicitly hypothetical acceptance examples, not application tests. Controls and availability can change; verify the cited manual against your installed version.
For work created in Imagild, carry the input requirements and acceptance checklist into the film workspace. The external software controls discussed above belong to their respective products.